Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T... www.e-t-a.de 1708 1 1 Description Typical applications Technical data Single, two and three pole magnetic and hydraulic-magnetic circuit breakers with trip-free mechanism and toggle actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics (S-type MO or HM CBE to EN 60934) ensures suitability for a wide range of applications. Featuring a combi-foot design for symmetric rail mounting. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 (IEC 60934). Power supplies, control equipment, communication systems, EDP systems. 8340-T... single pole three pole For further details please see chapter: Technical Information Voltage rating 3 AC 415V; AC 240V (50/60Hz); DC 80V (higher DC voltages to special order) Current rating range 0.02...50 A DC 0.02...30 A AC Auxiliary circuit 1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V Typical life 3 AC 415 V AC 240 V: 0.02...30 A 6,000 operations at 1 x I N , inductive 10,000 operations at 1 x I N , resistive WDC 80 V: 0.02...25 A 6,000 operations at 1 x I N , inductive 0.02...30 A 10,000 operations at 1 x I N , resistive 40 + 50 A 6,000 operations at 1 x I N , resistive Ambient temperature -40...+85 °C (-40...+185 °F) Insulation co-ordination rated impulse pollution (IEC 60664 and 60664A) withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) operating area test voltage AC 3,000 V Line to Load test voltage AC 1,500 V pole to pole (2- and 3-pole) test voltage AC 1,500 V main to auxiliary circuit test voltage AC 1,500 V Insulation resistance > 100 MΩ (DC 500 V) Interrupting capacity 6 x IN at AC; IEC 60934 - test sequence E 4 x IN at DC Interrupting capacity I N 0.02...20 A 25...30 A (UL 1077) AC: 1-pole AC 250 V/3,500A AC 250 V/3,500A 2-pole AC 250 V/3,500A AC 250 V/5,000A 3-pole 3AC 250V/3,500A 3AC250V/5,000A DC: 1-pole 0.02...50 A DC 80 V/3,500 A 2-pole 0.02...30 A DC 80 V/3500 A Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP20 Vibration with toggle down: 10 g at 0.9 I N directions 1, 2, 3, 4, 5: 10 g at 1 x I N with curves F1, F2: 10 g at 0.8 x I N in all planes. (57-2000 Hz) ± 0.76 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock directions 1, 2, 3, 4, 5: 100 g (11 ms) at 1 x I N direction 6: 100 g (11 ms) at 0.8 x I N with curves F1, F2: 100 g (11 ms) at 0.8 x I N to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH, to IEC 60068-2-78, test Cab Mass approx. 98 g per pole Standard current ratings and typical internal resistance values Current rating (A) Internal resistance values (Ω) per pole F1 F2 K1, M1, T1 K2, M2, T2 0,02 1 493 953 2 669 2 457 0,05 276 152 452 376 0,1 58 37 100 94 0,25 8,2 6,0 15,5 14,7 0,5 2,3 1,47 3,9 3,2 0,75 0,98 0,63 1,65 1,56 1 0,58 0,35 0,95 0,90 2 0,145 0,096 0,26 0,20 2,5 0,096 0,061 0,15 0,15 3 0,065 0,048 0,10 0,10 5 0,025 < 0,02 0,042 0,040 6 < 0,02 < 0,02 0,029 0,028 8 < 0,02 < 0,02 < 0,02 < 0,02 10 < 0,02 < 0,02 < 0,02 < 0,02 12 < 0,02 < 0,02 < 0,02 < 0,02 15 < 0,02 < 0,02 < 0,02 < 0,02 16 < 0,02 < 0,02 < 0,02 < 0,02 20 < 0,02 < 0,02 < 0,02 < 0,02 25 < 0,02 < 0,02 < 0,02 < 0,02 30 < 0,02 < 0,02 < 0,02 < 0,02 40 < 0,01 - < 0,01 - 50 < 0,01 - < 0,01 -

Articles in this issue

Links on this page

Archives of this issue

view archives of E-T-A - E-T-A Automation Products